2 presentations for load rejection:
Ground Fault Overvoltage with Inverter-Based Distributed Energy Resources841
Abstract
A Ground Fault Overvoltage (GFO) can occur in situations where an ungrounded transmission line and associated ungrounded transmission equipment is energized from distribution connected Distributed En... see moreergy Resource (DER) during a transmission single-phase-to-ground (SLG) fault. The condition could result in 1.73 pu overvoltage on phase to ground connected equipment which will be sustained until the DER ceases to energize the substation distribution transformer. Transmission equipment on the isolated circuit will be subjected to the above phase to ground overvoltage, also if there is frequency shift, the isolating transmission circuit breakers could potentially see up to 2.73 pu phase to ground overvoltage. Such an overvoltage can cause damage to customer or utility equipment and must be avoided. GFO concerns are already becoming a barrier to large-scale DER deployment either by posing low hosting capacity or by necessitating installation of costly mitigation equipment. Utilities need to study GFO risks and identify low-cost mitigation options to enable large-scale DER deployment. Given the fundamental differences in mechanisms and phenomena driving a GFO under DERs, classical GFO analysis methods do not apply to inverters, and advanced simulation methods and tools are required.
This presentation highlights EPRI’s work on GFO analysis, concerns, and evaluation of mitigation options using EMTP. The objective is to determine if or when high DER penetration presents a GFO problem and how to prioritize the mitigation and equipment evaluation. This includes evaluating the impact lightning arresters can have in reducing or clamping the overvoltage, the application and performance of high voltage substation overvoltage protection, and DER on-board voltage/frequency protection. The presentation further provides modeling recommendations for such a study using EMTP. As DER deployment increases, utilities will need to perform similar analysis to identify potential overvoltage risks and develop low-cost mitigation methods. This work provides a basis for such a study.
Tag(s): gfov, tov, ibr, DER, inverter, islanding, load rejection, inverter based resources
Author(s): N.K.Nathan - KNR Engineers
Type:Technical Presentation
Downloaded: 11
Date: 2021-06-17
Insulation Coordination Study of 765kV GIS SUBSTATION788
Abstract
Gas Insulated Substations provide cost effective solution due to reduced land requirements particularly in metropolitan area where power demand is registering steep growth. With the use of GIS technol... see moreogy, it is required to assess the risk of failure due to overvoltage. The Insulation Coordination study forms a very important aspect in design stage. This presentation deals with the IC study carried out for a large – 765/400/220kV GIS substation in a SUPER THERMAL POWER STATION in UTTAR PRADESH.
Due to the decreasing ratio of lightning impulse withstand voltage to the system voltage, the difference between LIOV and VFTO decreases and this factor calls for VFTO performance analysis for 765kV GIS as well.
The discussion includes modeling of Extra High Voltage GIS, Temporary Overvoltage (TOV), Lightning Impulse Overvoltage (LIOV), Switching Overvoltage (SOV) and Very fast transient Overvoltage (VFTO) performance analysis on 765kV GIS substation.
TOV typically caused by fault to ground, load rejections and energization of long lines are analyzed to decide the rating of the surge arrester.
LIOV simulation studies are carried out for possible onerous paths including longer and short paths to decide the location of the arrester. SOV analysis deals with the overvoltage due to switching operations during line energization, re-energization and fault occurrence and clearance.
The LIOV and SOV results have been validated with reference to protective levels prescribed. The VFTO analysis is performed with various GIS disconnector operations in accordance with the methodology and guidelines as per CIGRE WG D1.03-TB 519 and the results are validated with the limits specified.
Keywords: Insulation Coordination, VFTO, EHV, GIS, 765kV, Protective ratio.